APAR status
Closed as documentation error.
Error description
In "Preparing storage" (https://www.ibm.com/docs/en/baw/20.x?topic=workflow-preparing-s torage), the following information is missing: "For non-OpenShift Container Platforms (OCP), make sure that ansible-operator, otherwise known as userID 1001, has write permissions for the storage directory for operator pod persistent volume claims (PVC). You also need to make sure that dba-user, otherwise known as userID 50001, has permissions for the storage directory for non-operator pod PVCs." PRODUCTS AFFECTED IBM Business Automation Workflow
Local fix
Problem summary
No additional information is available.
Problem conclusion
The content will be updated the next time the documentation is refreshed.