Error description

  • The bootstrapProcessServerData command provokes a circular loop
    when "service-tracking-enabled" is set to false in the
    100Custom.xml and fails with the following error:
    1/19/21 10:07:11:865 CST] 00000001 Registry     E  CWLLG2035E:
    The registry was not initialized.  Error:
    java.lang.StackOverflowError
                                    java.lang.StackOverflowError
    followed by:
    Caused by: java.lang.NullPointerException
     at
    com.lombardisoftware.utility.spring.ProgrammaticTransactionSuppo
    rt.isInTransaction(ProgrammaticTransactionSupport.java:1123)
     at
    com.lombardisoftware.utility.spring.ProgrammaticTransactionSuppo
    rt.execute(ProgrammaticTransactionSupport.java:400)
     at
    com.lombardisoftware.utility.spring.ProgrammaticTransactionSuppo
    rt.execute(ProgrammaticTransactionSupport.java:342)
     at
    com.ibm.bpm.bootstrap.InstallationGuidHelper.loadInstallationGui
    d(InstallationGuidHelper.java:42)
    In the 100Custom.xml, we can see that the following setting:
    <service-tracking-enabledmerge="replace">false
    </service-trackin g-enabled>
    This means means that no tracking data will be emitted by the
    service flows. A change was done in BAW 20.0.0.2 to set
    service-tracking-enabled by default to "false" to always avoid
    the service flow engine to emit tracking data when running on
    Containers because PDW is not supported on BAW on Containers.
    This setting provokes a loop when getting the
    service-tracking-enabled property value when running the
    bootstrapProcessServerData command.
    

Local fix

  • n/a
    

Problem summary

  • When the service-tracking-enabled property is configured in the
    100Custom.xml file, running the bootstrapProcessServerData
    command fails with a java.lang.StackOverflowError exception.
    

Problem conclusion

  • A fix is available or will be available that ensures running the
     bootstrapProcessServerData command doesn't fail when the
    service-tracking-enabled property is configured in the
    100Custom.xml file.
    

Temporary fix

Comments

APAR Information

  • APAR number

    JR63248

  • Reported component name

    BUS AUTO WORKFL

  • Reported component ID

    5737H4100

  • Reported release

    K00

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2021-01-25

  • Closed date

    2021-01-28

  • Last modified date

    2021-01-28

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    BUS AUTO WORKFL

  • Fixed component ID

    5737H4100

Applicable component levels

[{"Line of Business":{"code":"LOB45","label":"Automation"},"Business Unit":{"code":"BU029","label":"Software"},"Product":{"code":"SS8JB4","label":"IBM Business Automation Workflow"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"20.0.0.1"}]

Document Information

Modified date:
21 June 2021