Direct link to fix
APAR status
Closed as program error.
Error description
In IBM Process Designer, you open a service flow before opening a process or business object. In the Service Flow editor, after you select an activity, the Implementation tab is blank. When you open the browser's JavaScript console, you see JavaScript errors such as Uncaught TypeError: Cannot read property 'concat' of undefined or Uncaught TypeError: Mod is not a constructor or Uncaught Error: declare: mixin #0 is not a callable constructor.
Local fix
Before opening a service flow, open a process or business object that you might have in the process app or toolkit. Then, open the service flow.
Problem summary
These errors occur because some JavaScript source files that the Service Flow editor needs have not loaded yet. PRODUCTS AFFECTED IBM Business Automation Workflow
Problem conclusion
A fix will be included in a future release that ensures all needed JavaScript source files are loaded into the Service Flow editor.
Temporary fix
Not applicable.
Comments
APAR Information
APAR number
JR63093
Reported component name
BUS AUTO WORKFL
Reported component ID
5737H4100
Reported release
J00
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2020-12-02
Closed date
2021-02-22
Last modified date
2021-08-04
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
BUS AUTO WORKFL
Fixed component ID
5737H4100
Applicable component levels
[{"Line of Business":{"code":"LOB45","label":"Automation"},"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SS8JB4","label":"IBM Business Automation Workflow"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"19.0.0.1"}]
Document Information
Modified date: