Direct link to fix
APAR status
Closed as program error.
Error description
The pivot table download script fails with a truncated data error because the SchemaGenerator tool doesn't read the actual column size from the LSW_BPD_INSTANCE_VARIABLES table. Instead, it uses a hard-coded 512 column size when creating the LSW_BPD_INSTANCE_VARS_PIVOT table so that the script will cause the DataLoad tool to fail if the size of the value inserted into the column exceeds 512 characters when the DataLoad tool runs to populate the pivot table. You see this stack trace: Jul 10, 2018 6:21:51 PM FINE: com.microsoft.sqlserver.jdbc.SQLServerException - *** SQLException: com.microsoft.sqlserver.jdbc.SQLServerException: String or binary data would be truncated. Msg 8152, Level 16, State 13, String or binary data would be truncated. Jul 10, 2018 6:21:51 PM SEVERE: com.lombardisoftware.tools.optimization.search.DataLoad - Error while processing 81787 com.microsoft.sqlserver.jdbc.SQLServerException: String or binary data would be truncated. at com.microsoft.sqlserver.jdbc.SQLServerException.makeFromDatabase Error(SQLServerException.java:216) at com.microsoft.sqlserver.jdbc.SQLServerStatement.getNextResult(SQ LServerStatement.java:1515) at com.microsoft.sqlserver.jdbc.SQLServerPreparedStatement.doExecut ePreparedStatement(SQLServerPreparedStatement.java:404) at com.microsoft.sqlserver.jdbc.SQLServerPreparedStatement$PrepStmt ExecCmd.doExecute(SQLServerPreparedStatement.java:350) . . . PRODUCTS AFFECTED IBM Business Process Manager (BPM) Advanced IBM BPM Standard IBM BPM Express IBM Business Automation Workflow
Local fix
Increase the size of the generated column in LSW_BPD_INSTANCE_VARS_PIVOT to match the size in lsw_bpd_instance_variables. Run SQL command ALTER TABLE bpmadmin.LSW_BPD_INSTANCE_VARS_PIVOT ALTER COLUMN [variableName] NVARCHAR(newSize) where variableName is the instance variable with value in "STRING_VALUE" column which exceeds 512 characters and newSize is the size that will accommodate the instance variable (ie. 1024).
Problem summary
No additional information is available.
Problem conclusion
A fix that ensures the SchemaGenerator tool reads the actual column size of the string values from LSW_BPD_INSTANCE_VARIABLES table instead of using a hard-coded 512 size will be available in a future release of IBM Business Automation Workflow.
Temporary fix
Comments
APAR Information
APAR number
JR59774
Reported component name
BPM ADVANCED
Reported component ID
5725C9400
Reported release
I00
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2018-07-18
Closed date
2018-08-21
Last modified date
2018-08-21
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
BUS AUTO WORKFL
Fixed component ID
5737H4100
Applicable component levels
RI00 PSY
UP
[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SS8JB4","label":"IBM Business Automation Workflow"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"18.0.0.0","Edition":"","Line of Business":{"code":"LOB45","label":"Automation"}}]