A fix is available
APAR status
Closed as program error.
Error description
Communications Server for Windows --------------------------------- When an SSCP takeover occurs, some TN3270 printers lose connection with the server.
Local fix
Restart the printer connection.
Problem summary
If a printer application is using an LU but is not in session (not bound) and an SSCP takeover occurs, then when a warm ACTLU is received (and a cold ACTLU RSP is sent) an error is reported to the printer application, disconnecting the printer. The printer application can re-connect. This problem affects all printer LUs, whether connected by TN3270 or API.
Problem conclusion
This error is not necessary to report, because the printer is not interested in the SSCP "MSG 10" or "start of day" screen. Code has been changed for printer LUs to not treat the warm ACTLU as a reset. This change has no effect if the LU is active in session or if it is not a printer LU.
Temporary fix
Comments
APAR Information
APAR number
JR46205
Reported component name
COMM SERV NT 6.
Reported component ID
5639F2503
Reported release
613
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2013-04-02
Closed date
2013-04-02
Last modified date
2013-04-02
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
COMM SERV NT 6.
Fixed component ID
5639F2503
Applicable component levels
R613 PSY
[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSHQNF","label":"Communications Server for Windows"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"613","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]