Error description
The ODBC Enterprise write job is failing with the following error message. [IBM (DataDirect OEM)][ODBC DB2 Wire Protocol driver]String data code page conversion failed. Error in parameter 1. (0) When the job failed, it was noticed that the following error messages are seen in the ODBC traces. 1. ODBC Traces showing Error message driver manager: DIAG [HY090] [Microsoft][ODBC Driver Manager] Invalid string or buffer length (0) 2. DIAG [HY000] [IBM (DataDirect OEM)][ODBC DB2 Wire Protocol driver]String data code page conversion failed. Error in parameter 1. (0)
Local fix
Problem summary
The ODBC Enterprise write job is failing with the following error message. [IBM (DataDirect OEM)][ODBC DB2 Wire Protocol driver]String data code page conversion failed. Error in parameter 1. (0)
Problem conclusion
Un-initialized buffer was causing any value to be passed. For ODD and -ve value SQLGetInfoW function call was failing. Standards says value should be either 0 or EVEN number.
Temporary fix
Comments
APAR Information
APAR number
JR45919
Reported component name
WIS QUALITYSTAG
Reported component ID
5724Q36QS
Reported release
850
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2013-03-05
Closed date
2013-03-18
Last modified date
2013-03-18
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
WIS QUALITYSTAG
Fixed component ID
5724Q36QS
Applicable component levels
R850 PSY
UP