Error description
During performance analysis of the high degree of chattiness between the Process Designer and Process Center on BPM 7.5.1, we found that extra network trips are made.
Local fix
N/A
Problem summary
**************************************************************** * USERS AFFECTED: Users of BPM Express, BPM Standard and BPM * * Advanced. * **************************************************************** * PROBLEM DESCRIPTION: During performance analysis of the * * high degree of chattiness * * between the Process Designer and * * Process Center on BPM 7.5.1, * * we found that extra network trips are * * made. * **************************************************************** * RECOMMENDATION: * **************************************************************** During performance analysis of the high degree of chattiness between the Process Designer and Process Center on BPM 7.5.1, we found that extra network trips are made. Changes were done to remove 2 server trips per EJB call. For networks with high latency, this makes a big difference.
Problem conclusion
The extra network trips were removed and performance improved. The fix is available as a part of the JR42012 ifix package (http://www-01.ibm.com/support/docview.wss?uid=swg1JR42012) and needs to be installed as follows: - Install JR42012 on both Process Designer and Process Center/Server using IM - On Process Center/Server run bpmprofileUpgrade as outlined in http://www-01.ibm.com/support/docview.wss?uid=swg27022245#recove rFailure
Temporary fix
Comments
APAR Information
APAR number
JR42113
Reported component name
BPM ADVANCED
Reported component ID
5725C9400
Reported release
751
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2012-02-29
Closed date
2012-04-18
Last modified date
2012-04-18
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
BPM ADVANCED
Fixed component ID
5725C9400
Applicable component levels
R750 PSY
UP
[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSFTN5","label":"IBM Business Process Manager Advanced"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"7.5.1","Line of Business":{"code":"LOB45","label":"Automation"}}]
Document Information
Modified date:
12 October 2021