Error description
Datastage job aborts when using DataDirect ODBC driver to insert date values = 9999-12-31 Error message received = Datetime field overflow
Local fix
Problem summary
Datastage job aborts when using DataDirect ODBC driver to in date values = 9999-12-31
Problem conclusion
ODBC Connector was binding the date type as smalldatetime for MS SQL server,hence 9999-12-31 gave Datetime overflow error Corrected the binding length for date type for MS SQL Server
Temporary fix
Comments
APAR Information
APAR number
JR39639
Reported component name
WIS DATASTAGE
Reported component ID
5724Q36DS
Reported release
850
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2011-05-23
Closed date
2011-06-02
Last modified date
2011-11-28
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
WIS DATASTAGE
Fixed component ID
5724Q36DS
Applicable component levels
R850 PSY
UP