APAR status
Closed as duplicate of another APAR.
Error description
Customer is trying to go into DataStage director, clicks on a job and click New Monitor. He receives the error: Run-time error '13' Type mismatch and the monitor won't open. The issue is that they have the short date format in the regional settings set to: ddd MM/dd/yyyy with no seperator. They must use the default format of M/d/yyyy with a / seperator. Even if they use ddd/M/d/yyyy with the slash seperator it doesn't like it. The server is 8.0.1 FP1A windows 2003
Local fix
GO into regional settings and change the date format back to the default M/d/yyyy with a / seperator
Problem summary
Problem conclusion
Temporary fix
Comments
This APAR was raised before I had identified that the issue had already been resolved in another code branch. This APAR is a duplicate of JR29851
APAR Information
APAR number
JR31745
Reported component name
WIS DATASTAGE
Reported component ID
5724Q36DS
Reported release
801
Status
CLOSED DUB
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2009-01-21
Closed date
2009-01-28
Last modified date
2009-01-28
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Applicable component levels
[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSVSEF","label":"IBM InfoSphere DataStage"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"8.0.1","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]
Document Information
Modified date:
28 January 2009