Error description
When running HPR to an adjacent control point there were multiple RTP pipes for 1 COS. Each new LU-LU session would drive a new RTP pipe for the same COS. There should be only 1 RTP pipe for each COS.
Local fix
remove any adjacent linkstation routing profiles previously used for SUBAREA.
Problem summary
**************************************************************** * USERS AFFECTED: All running HPR between CS/WIN to a * * VTAM host with adjacent link profiles * * present in the acg. * **************************************************************** * PROBLEM DESCRIPTION: If the ACG (config) file still * * contains the old subarea linkstation * * routing profiles and your now using * * APPN and HPR to the host, you can * * see multiple rtp pipes for the LU-LU * * COS, one for each session. * * * **************************************************************** * RECOMMENDATION: * **************************************************************** The logic for comparing the RTP pipes to check for a suitable one was done before we knew the actual remote NCE. Therefore, the requested RTP connection failed to match with an existing suitable one.
Problem conclusion
The actual NCE is noted after the RSETUP response is received and a check done to see if an existing pipe matches the requested new one.
Temporary fix
Comments
APAR Information
APAR number
JR28562
Reported component name
COMM SERV NT 6.
Reported component ID
5639F2503
Reported release
613
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2008-02-22
Closed date
2008-02-22
Last modified date
2009-06-17
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Modules/Macros
SNAPS
Fix information
Fixed component name
COMM SERV NT 6.
Fixed component ID
5639F2503
Applicable component levels
R612 PSY
UP
R613 PSY
UP
[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSHQNF","label":"Communications Server for Windows"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"613","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]
Document Information
Modified date:
07 January 2022