A fix is available
APAR status
Closed as program error.
Error description
Attempting to configure or open a QLogic FC adapter can hang the FC device driver if the link up fails.
Local fix
Problem summary
Attempting to configure or open a QLogic FC adapter can hang the FC device driver if the link up fails.
Problem conclusion
Ensure the FC protocol driver is not awakened by the FC adapter driver unless and until all state bits are properly set, and ensure all state bits are properly cleared before retrying the open.
Temporary fix
Comments
5300-10 - use AIX APAR IZ90973 5300-11 - use AIX APAR IZ90818 5300-12 - use AIX APAR IZ90740 6100-03 - use AIX APAR IZ93797 6100-04 - use AIX APAR IZ93614 6100-05 - use AIX APAR IZ87050 6100-06 - use AIX APAR IZ93078 6100-06 - use AIX APAR IZ87972 6100-07 - use AIX APAR IZ88340 7100-00 - use AIX APAR IZ87183
APAR Information
APAR number
IZ90973
Reported component name
AIX 5.3
Reported component ID
5765G0300
Reported release
530
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Submitted date
2010-12-14
Closed date
2010-12-14
Last modified date
2013-03-24
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
AIX 5.3
Fixed component ID
5765G0300
Applicable component levels
R530 PSY U840543
UP11/02/23 I 1000
PTF to Fileset Mapping
U840543 devices.pci.77102224.com 5.3.10.6