Error description
Seeding an RTEMS that is across a firewall from the HUB will fail either the firewall is NAT'd or ephemeral is explicitly set for the RTEMS connection. RECREATE INSTRUCTIONS: Install a HUB TEMS and two RTEMS, all on Unix and/or Linux. Install the HUB and one RTEMS in the same lab Install the other RTEMS in a different lab, across a firewall. Configure both RTEMS using EPHEMERAL:Y as follows: 1) Configure both RTEMS and then add EPHEMERAL:Y to beginning of the KDC_FAMILIES variable. -OR- 2) Follow the instructions in http://www-01.ibm.com/support/docview.wss?uid=swg21390561 Start the HUB TEMS first, then the two RTEMS. Run itmcmd support -t TEMSNAME ux from each of the TEMS Review the logs and notice that the RTEMS from other lab across the firewall from the HUB failed seeding. The cat and atr files were copied, but the sql processing was not successful.
Local fix
Run kdstsns interactively
Problem summary
Seeding a remote monitoring server that is across a firewall from the hub monitoring server will fail when either the firewall is NAT'd or ephemeral is explicitly set for the remote monitoring server connection.
Problem conclusion
The seeding tool has been updated to allow it to work correctly when a remote monitoring server is across a firewall from the hub monitoring server. The fix for this APAR is contained in the following maintenance packages: | fix pack | 6.2.2-TIV-ITM-FP0003
Temporary fix
Comments
APAR Information
APAR number
IZ79757
Reported component name
OMEG DIST INSTA
Reported component ID
5608A41CI
Reported release
622
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2010-07-09
Closed date
2010-08-11
Last modified date
2010-10-04
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
OMEG DIST INSTA
Fixed component ID
5608A41CI
Applicable component levels
R622 PSY
UP
[{"Line of Business":{"code":"LOB45","label":"Automation"},"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSTFXA","label":"Tivoli Monitoring"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"622"}]
Document Information
Modified date:
30 December 2022