APAR status
Closed as documentation error.
Error description
An XMS .net application sets the connection factory property XMSC.WMQ_CCDTURL and tries to connect to WMQ, receives an error CWSMQ0006E.
Local fix
Use MQ environment variables MQCHLIB and MQCHLTAB to point to the MQ CCDT.
Problem summary
**************************************************************** USERS AFFECTED: Users of XMS .NET application who sets the XMSC.WMQ_CCDTURL connection factory Platforms affected: Windows **************************************************************** PROBLEM SUMMARY: XMS .net Documentation needs to update to reflect the following behaviour of the XMS. Setting Client Channel Definition Table (CCDT) through URL is not supported in WMQ .net clients and thus setting the value of XMSC.WMQ_CCDTURL in XMS is ignored.
Problem conclusion
XMS .NET documentation needs to be updated at https://ut-ilnx- r4.hursley.ibm.com/xms/help/topic/com.ibm.websphere.xms.net.pdf. doc_2.0.0/dqx5prx_wmq_ccdt_url.htm#dqx5prx_wmq_ccdt_url with the following words : Setting Client Channel Definition Table (CCDT) through URL is not supported in WMQ .net clients and thus setting the value of XMSC.WMQ_CCDTURL in XMS is ignored. ---------------------------------------------------------------
Temporary fix
Comments
APAR Information
APAR number
IZ76986
Reported component name
MSG SRVCS CL .N
Reported component ID
5724M2100
Reported release
200
Status
CLOSED DOC
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2010-06-07
Closed date
2010-06-08
Last modified date
2010-06-08
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Applicable component levels
[{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCRTPP","label":"SupportPac"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"2.0","Edition":"","Line of Business":{"code":"","label":""}}]
Document Information
Modified date:
08 June 2010