Fixes are available
APAR status
Closed as program error.
Error description
An 0xC0000005 exception (ACCESS_VIOLATION) occurred on a Windows 2003 RTEMS whenever an AIX HTEMS would go down (ITM 6.2.2 FP01 being used). Based on information found in the documentation, this is a storage overlay problem, which is covered by CMVC defect 124429. All documentation (crash dumps) showed a stack corruption with text data: WARNING: Frame IP not in any known module. Following frames may be wrong.
Local fix
N/A
Problem summary
The management server terminates abnormally with an access violation error in function OpLogReader::SetMSG2EmitBuffer(). The management server generates an "access violation" exception with the following call stack: #0 0x00000200006089e6 in memcpy () from /lib64/tls/libc.so.6 #1 0x0000020004c4ec9e in OpLogReader::SetMSG2EmitBuffer () from /products/ITM621/ls3266/ms/lib/KRANDREG The exception occurs when the management server attempts to write a MSG2 message exceeding 255 characters into the management server OPLOG table.
Problem conclusion
Code changes were made to ensure that only 255 characters are written to the management server OPLOG table. If an agent generates a message exceeding 255 characters, the message will be truncated. The fix for this APAR is contained in the following maintenance packages: | fix pack | 6.2.2-TIV-ITM-FP0003
Temporary fix
Comments
APAR Information
APAR number
IZ76521
Reported component name
TEMS
Reported component ID
5724C04MS
Reported release
622
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2010-05-26
Closed date
2010-06-27
Last modified date
2010-10-01
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
TEMS
Fixed component ID
5724C04MS
Applicable component levels
R622 PSY
UP