Fixes are available
APAR status
Closed as program error.
Error description
After re-cycling multiple rTEMS, situations fail to start because an agent has switched during the restart and the situation has been deleted from the situation description table of the rTEMS that the agent switched away from. When the agent switches back to that rTEMS, the situation cannot start. RECREATE INSTRUCTIONS: Not recreatable without special wait timers inserted into the product to force the exact sequence of events to occur.
Local fix
Start each rTEMS sequentially and allow to complete its start-up before proceeding with the next rTEMS.
Problem summary
After a remote management server is restarted and agents have connected back, situations fail to start for some agents.
Problem conclusion
If the timing is just right between the agent switch to secondary and the recycling management servers' heartbeat processing, the access list cache won't be cleared at the HUB management server for the restarting management server. The logic has been updated so that the data is properly cleared and handled. The fix for this APAR is included in the following maintenance vehicle: | fix pack | 6.2.1-TIV-ITM-FP0003
Temporary fix
Comments
APAR Information
APAR number
IZ76004
Reported component name
TEMS
Reported component ID
5724C04MS
Reported release
621
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2010-05-13
Closed date
2010-06-25
Last modified date
2010-07-22
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
TEMS
Fixed component ID
5724C04MS
Applicable component levels
R621 PSY
UP