Error description
Approver: DK Enter the L2 engineer who did the recreate or "None": None L2 engineer: John Alvord Environment: ITM 6.2 FP1 AIX 5.3 Unix OS Agent, Agent support library Do you think the latest patch applied is involved? No Problem Description: Customer sets historical sampling interval to 1 minute. The data is actually recorded every 62 seconds. Detailed Recreation Procedure: See above. Related Files and Output: See ECUREP where several logs are recorded.
Local fix
Problem summary
When the customer sets historical sampling interval to 1 minute, the data is actually recorded every 62 seconds. This is because the agent takes 2 seconds for each sample and the sample expiry timer does not take this time into account while setting the timer to expire the next time.
Problem conclusion
The code has been modified to keep track of the time taken to get the sample from the agent, and then subtract it from the sampling interval while setting the next timer expiration. Note: If the sampling interval is less than 1 minute and activity is high, the data collection time might be longer. This might have an effect on the expiration time and number of samples taken. This is beyond program control. The fix for this APAR is contained in the following maintenance packages: | fix pack | 6.2.0.3-TIV-ITM-IF0001
Temporary fix
Comments
APAR Information
APAR number
IZ54463
Reported component name
TEMS
Reported component ID
5724C04MS
Reported release
620
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2009-07-01
Closed date
2009-07-21
Last modified date
2009-07-21
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
TEMS
Fixed component ID
5724C04MS
Applicable component levels
R620 PSY
UP
[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SSCTLMP","label":"ITM Tivoli Enterprise Mgmt Server V6"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"620","Edition":"","Line of Business":{"code":"","label":""}}]
Document Information
Modified date:
21 July 2009