Error description
Environment: ITM 6.2.1 Windows platform Problem: The pdcollect command does not get the logs. It creates a "logs" subdirectory, but the contents are empty. Recreation Steps: Note that the "-nologs" argument is NOT being used, a simple "pdcollect" command without arguments will have the problem in ITM 6.2.1. Approver: KD
Local fix
Change the following line in the %CANDLE_HOME%\bin\pdcollect.cmd file from this: dir /s /ad /b "%PROD_HOME%" | %SYSTEMROOT%\system32\find /i "logs" | "%FILTDIR%\pdcfilt" "%PROD_HOME%\" >logfile.lst to this: dir /s /ad /b "%PROD_HOME%" | %SYSTEMROOT%\system32\find /i "logs" | "%FILTDIR%\pdcfilt" "%PROD_HOME%\\" >logfile.lst
Problem summary
The pdcollect command does not get the logs. It creates a "logs" subdirectory, but the contents are empty.
Problem conclusion
The problem was related to syntax error on calling internal binary program. The fix for this APAR is contained in the following maintenance packages: | fix pack | 6.2.1-TIV-ITM-FP0001
Temporary fix
Comments
APAR Information
APAR number
IZ42859
Reported component name
OMEG DIST INSTA
Reported component ID
5608A41CI
Reported release
621
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2009-01-30
Closed date
2009-10-14
Last modified date
2009-12-11
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
ITM WEB SERVICE
Fixed component ID
5724C04WS
Applicable component levels
R621 PSY
UP
[{"Line of Business":{"code":"LOB45","label":"Automation"},"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSTFXA","label":"Tivoli Monitoring"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"621"}]
Document Information
Modified date:
30 December 2022