APAR status
Closed as program error.
Error description
1. Go to Assets - Failure Codes and create a Failure Code FC1 2. Add a problem P1 in the Problems tab via the New Row button 3. Add a cause C1 in the Causes for P1 tab 4. Add a remedy R1 in the Remedies for C1 tab. 5. Add a new Failure Code : Repeat the steps 1-4 above for a new Failure Code FC2 (add a problem P2, cause C2, remedy R2) 6. Go to Assets - Location (Oil) and create a new Location L1 7. Apply to Primary System 8. Add Boiler as the Parent 9. Apply Failure Class FC1 to this Location 10. Activate this Location L1 11. Create a new Location L2, repeat steps 6-7-8 12. Apply Failure Code FC2 to this location 13. Activate Location L2 14. Go to Assets - Assets (Oil) 15. Create a new Assest A1 and associate it with Location L1, apply Failure Class FC1 and change status to active 16. Create a new Assest A2 and associate it with Location L2, apply Failure Class FC2 and change status to active 17. Go to Work Orders - Work Order Tracking (Oil) and create a new Work Order : 1208 18. Apply location L1 and Assest A1 to this WO and choose Problem code P1 19. Save Work Order 20. Go to Failure Reporting tab and check Failure Codes table, there the problem code P1 shows in the Failure Codes section (CORRECT) 21. In the WO main tab, change to location to L2 and click on the question mark: a warning pop-up shows, click Yes to apply L2. 22. Now the Problem Code field is empty. 23. Click on the Select Value icon for the Problem Code field and choose P2 from the pop-up 24. After this selection, P2 is correctly populated. 25. Go to Failure Reporting tab WITHOUT SAVING THE RECORD. There is no Failure Codes section present (THIS IS THE ISSUE) The expectation is that the Failure Codes section should contain Problem Code P2
Local fix
N/A
Problem summary
**************************************************************** * USERS AFFECTED: * * All Maximo Oil and Gas 7510 and Maximo HSE 7510 users * **************************************************************** * PROBLEM DESCRIPTION: * * FAILURE CODE SECTION DISAPPEARS AFTER CHANGING * * THELOCATION/ASSET * **************************************************************** * RECOMMENDATION: * ****************************************************************
Problem conclusion
A fix was provided
Temporary fix
Comments
APAR Information
APAR number
IV98464
Reported component name
MAXIMO OIL & GA
Reported component ID
5724R5400
Reported release
751
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2017-07-26
Closed date
2017-08-11
Last modified date
2017-08-11
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
MAXIMO OIL & GA
Fixed component ID
5724R5400
Applicable component levels
R751 PSY
UP
[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSLL9G","label":"Maximo for Oil and Gas"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"751","Edition":"","Line of Business":{"code":"LOB59","label":"Sustainability Software"}}]