APAR status
Closed as program error.
Error description
A Characteristic or Guage meter of an asset has a value and datetime. If you try and enter an identical datetime against this meter you get differing results, depemnding on how you enter the meter reading. Scenario1: If you try and enter the meter reading by clicking on the Chevrons next to the Asset field in the Multiple Assets, Locations and CI's section of a Work Order (In the WO tracking application), then you get the error: BMXAA2907 - Measurements cannot share the same date and time. Scenario 2: If however, you go to the Assets application and find the same asset as above and enter the same Meter Reading from the More Actions menu, then the meter reading is entered against the asset without any error. STEPS TO REPRODUCE: ------------------------ 1. Create a new Asset "AS10000013" adding a Gauge type Meter in Meters section on Meters tab. 2. Create a new WO "WO10000183" specifying "AS10000013" in Assets field. 3. Create another new WO "WO10000184" adding the asset "AS10000013" in "Multiple Assets,Locations and CIs" section. 4. From WOTRACK, open "WO10000183" and "Enter Meter Readings" and specify "200" for "New Reading" and "17/06/21 0:00" for "New Reading Date". 5. From WOTRACK, open "WO10000184" and select "Enter Meter Reading" after clicking "Detail Menu" button located right next to the asset in "Multiple Assets,Locations and CIs" section. 6. On "Enter Meter Readings" window, specify "100" in "New Reading" and same date time "2017/06/21 0:00" in "New Reading Date". 7. Click OK then you will see the following error. 8. Close System Message window by clicking OK and then you will see the following error. 9. Open WO WO10000183 and select "Enter Meter Readings" from "More Actions" menu 10. Specify "100" in "New Reading" and "17/06/21 0:00" in "New Reading Date" in the same way. 11. Click OK and then no error is displayed this time. 12. From Assets, open "AS10000013" and select "Manage Meter Reading History" to see the change was made.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: * * MAXIMO * **************************************************************** * PROBLEM DESCRIPTION: * * AN ASSET METER HAS A VALUE AND DATETIME. ENTERING AN * * IDENTICAL DATETIME AGAINST THIS METER GIVES VARYING RESULTS. * **************************************************************** * RECOMMENDATION: * ****************************************************************
Problem conclusion
The fix for this APAR is contained in the following maintenance package: | release\fix pack | Interim Fix for Release 7.6.0.9 Product
Temporary fix
Comments
APAR Information
APAR number
IV97448
Reported component name
ASSETS
Reported component ID
5724R46AS
Reported release
760
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2017-06-22
Closed date
2017-06-26
Last modified date
2017-06-26
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
ASSETS
Fixed component ID
5724R46AS
Applicable component levels
R760 PSY
UP
[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSLKT6","label":"IBM Maximo Asset Management"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"760","Edition":"","Line of Business":{"code":"LOB59","label":"Sustainability Software"}}]