APAR status
Closed as fixed if next.
Error description
Following an upgrade to 6.3 FP7, users in the "OPERATOR" group are no longer able to login correctly, they receive an empty console. This is rectified by adding the permission - ""UserAdministration: View" to the account, then they can login successfully. This, however, seems to have been previously identified as unwanted behaviour as per PMR 48161,211,788 and an APAR was raised - IV77992. This APAR was included in FP7 but we still have customers encountering this behaviour.
Local fix
This is rectified by adding the permission - "UserAdministration: View" to the account, then they can login successfully.
Problem summary
Please use the documented work around until the fix is available in a new release.
Problem conclusion
Temporary fix
Comments
APAR Information
APAR number
IV97405
Reported component name
TEPS
Reported component ID
5724C04PS
Reported release
630
Status
CLOSED FIN
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2017-06-22
Closed date
2018-08-03
Last modified date
2018-08-03
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Applicable component levels
[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSTFXA","label":"Tivoli Monitoring"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"630","Line of Business":{"code":"LOB45","label":"Automation"}}]