IBM Support

IV96648: EBP REGISTER HOLDS INCORRECT VALUE

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • Error Message: Various symptoms can occur such as a crash,
    unexpected exceptions or incorrect behaviour.
    .
    Stack Trace: N/A
    .
    This problem can only occur on X86 32-bit systems.
    

Local fix

  • The following environment variable needs to be set to avoid the
    problem.
    TR_DisableEBPasGPR=1
    

Problem summary

  • The JIT compiler uses the EBP register as both a general purpose
    register as well as for holding JVM internal pointers on X86
    32-bit systems. At various points in a JIT compiled method, EBP
    needs to contain a JVM internal pointer, and so the value it
    previously held as a general purpose register needs to be moved
    and preserved. The JIT compiler was not correctly handling all
    of these cases, so it is possible for the incorrect value to be
    in EBP.
    

Problem conclusion

  • The JIT compiler has been updated to no longer use EBP as a
    general purpose register on X86 32-bit systems.
    .
    This APAR will be fixed in the following Java Releases:
       8    SR4 FP6   (8.0.4.6)
       8    SR5 FP10  (8.0.5.10)
    .
    Contact your IBM Product's Service Team for these Service
    Refreshes and Fix Packs.
    For those running stand-alone, information about the available
    Service Refreshes and Fix Packs can be found at:
               https://www.ibm.com/developerworks/java/jdk/
    

Temporary fix

Comments

APAR Information

  • APAR number

    IV96648

  • Reported component name

    JIT

  • Reported component ID

    620700124

  • Reported release

    130

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2017-05-26

  • Closed date

    2017-05-26

  • Last modified date

    2018-08-13

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    JIT

  • Fixed component ID

    620700124

Applicable component levels

[{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSC9HBA","label":"Just In Time (JIT) Compiler"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"130","Edition":"","Line of Business":{"code":"","label":""}}]

Document Information

Modified date: