APAR status
Closed as program error.
Error description
Error Message: Application threads are waiting on the ValueProfilingMutex lock to be released by a JIT compiler thread causing the application to hang. This can be seen in the javacore*.txt generated by the JVM's dump agent. . Stack Trace: N/A .
Local fix
This option may be avoided using the following Java option: -Xjit:disableProfiling
Problem summary
The JIT compiler threads will acquire and release the ValueProfilingMutex lock during compilation. The lock is also used by application threads as part of application profiling by the JIT compiler. It is possible for a compilation to abort due to it exceeding thresholds. In some scenarios, the ValueProfilingMutex lock was not being released when a compilation thread that acquired it aborted the compilation causing the lock to be held by that thread indefinitely. If this happens, then application threads wanting to acquire that lock as part of profiling will endlessly wait to acquire this lock causing the application to hang.
Problem conclusion
The JIT compiler has been updated to release the ValueProfilingMutex lock when a compilation is aborted. . This APAR will be fixed in the following Java Releases: 8 SR3 FP22 (8.0.3.22) 7 SR10 (7.0.10.0) 7 R1 SR4 (7.1.4.0) 6 R1 SR8 FP40 (6.1.8.40) 6 SR16 FP40 (6.0.16.40) . Contact your IBM Product's Service Team for these Service Refreshes and Fix Packs. For those running stand-alone, information about the available Service Refreshes and Fix Packs can be found at: https://www.ibm.com/developerworks/java/jdk/
Temporary fix
Comments
APAR Information
APAR number
IV91347
Reported component name
JIT
Reported component ID
620700124
Reported release
130
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2016-12-07
Closed date
2016-12-22
Last modified date
2017-01-05
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
JIT
Fixed component ID
620700124
Applicable component levels
R130 PSY
UP
R260 PSY
UP
R600 PSY
UP
[{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSC9HBA","label":"Just In Time (JIT) Compiler"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"130","Edition":"","Line of Business":{"code":"","label":""}}]
Document Information
Modified date:
05 January 2017