APAR status
Closed as program error.
Error description
STEPS TO REPRODUCE: - Go to System Properties application. - Find the webclient.useClientTimer property. - Its value is already set to = 1 - Go to Work Order Tracking application - Find an existing WO record (e.g. in Wappr status) - Open the Calendar lookup for any DateTime field, such as Scheduled Start - The TimePicker on the right shows a number of timeslots. - The range of the timeslots is 12.00am (midnight) - 2.45am - This is always the case regardless of the client machine's local time - It should show a range of timeslots showing a 2-hour range matching the current DateTime on the client machine - The webclient.useClientTimer property's value of 1 is therefore not taken into account CURRENT ERRONEOUS RESULT: The webclient.useClientTimer property's value of 1 is therefore not taken into account EXPECTED RESULT: If webclient.useClientTimer = 1, then the Time picker should adjust to display timeslots matching the current System DateTime (including one hour before SYSDATE and one hour after SYSDATE) ADDITIONAL INFO: This was working in Maximo 7.5.0.x up to Maximo 7.5.0.7 New system property 'webclient.useClientTimer' was then added to adjust the default time on the Date/Time Calendar widget to use the client workstation's local time.
Local fix
Users need to scroll down to the relevant timeslot close to current SysDateTime.
Problem summary
**************************************************************** * USERS AFFECTED: * * All Maximo Users * **************************************************************** * PROBLEM DESCRIPTION: * * Time picker on calendar lookup defaults to 12.00am. * **************************************************************** * RECOMMENDATION: * * Upgrade to latest release * **************************************************************** STEPS TO REPRODUCE: - Go to Work Order Tracking application - Find an existing WO record (e.g. in Wappr status) - Open the Calendar lookup for any DateTime field, such as Scheduled Start - The TimePicker on the right shows a number of timeslots. - The range of the timeslots is 12.00am (midnight) - 2.45am - This is always the case regardless of the client machine's local time - It should show a range of timeslots showing a 2-hour range matching the current DateTime on the client machine CURRENT ERRONEOUS RESULT: Time picker on calendar lookup does not display the correct range of times. EXPECTED RESULT: Time picker should adjust to display timeslots matching the current System DateTime.
Problem conclusion
Time picker on calendar lookup shows a range of times that includes the selected time or current time. The fix for this APAR is contained in the following maintenance package: | release\fix pack | Fix Pack Release 7.6.0.8 TPAE
Temporary fix
Comments
APAR Information
APAR number
IV90424
Reported component name
SYSTEM CONFIG
Reported component ID
5724R46S1
Reported release
760
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2016-11-01
Closed date
2017-02-23
Last modified date
2017-02-23
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Modules/Macros
MAXIMO
Fix information
Fixed component name
SYSTEM CONFIG
Fixed component ID
5724R46S1
Applicable component levels
R760 PSY
UP
[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSLKT6","label":"IBM Maximo Asset Management"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"760","Edition":"","Line of Business":{"code":"LOB59","label":"Sustainability Software"}}]
Document Information
Modified date: