APAR status
Closed as program error.
Error description
If you set Exection mode in Cognos 10.2 to 64-bit you won' tbe able to publish any Object Structres from maximo into Cognos packages PROBLEM: Cannot use packages published from Maximo when Report Server Execution Mode is 64-bit PERFORMANCE ISSUE: n/a STEPS TO REPRODUCE: set the Report Server Execution Mode in Cognos to 64 bit, try publishing any object structure to cognos CURRENT ERRONEOUS RESULT: QFS-ERR-0141 This report service is configured as 64-bit and only supports packages published with the dynamic query mode. EXPECTED RESULT: Package should be received into Cognos ADDITIONAL INFO: This is a regression, the issue was previously fixed under this APAR: IV38240 COGNOS 10.1.1 64BIT SUPPORT FOR RUNNING REPORTS FROM MAXIMO ENVIRONMENT (SYSTEM INFO): LOCAL FIX: don't use 64 bit execution mode in Cognos
Local fix
don't use 64 bit execution mode in Cognos
Problem summary
**************************************************************** * USERS AFFECTED: * * Cognos report administrators. * **************************************************************** * PROBLEM DESCRIPTION: * * Cannot use packages published from Maximo when Report Server * * Execution Mode is 64-bit (dyamic query mode). * **************************************************************** * RECOMMENDATION: * * Use compatability mode or upgrade to latest release. * ****************************************************************
Problem conclusion
Set the mxe.report.cognos.querymode property to "dynamic". The fix for this APAR is contained in the following maintenance package: | release\fix pack | Fix Pack Release 7.6.0.6 TPAE
Temporary fix
Comments
APAR Information
APAR number
IV87641
Reported component name
COGNOS INTEG-SY
Reported component ID
5724R46C2
Reported release
760
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2016-08-04
Closed date
2016-10-01
Last modified date
2016-10-01
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
COGNOS INTEG-SY
Fixed component ID
5724R46C2
Applicable component levels
R760 PSY
UP