A fix is available
APAR status
Closed as program error.
Error description
Uplift GSKit to 8.0.50.60 or higher so that the following work-around can be applied to resolve the Fujitsu issue. 17-Mar-2016: GSKit hang on Fujitsu SPARC64-X (Same as M.10) The Issue: We have received multiple reports that GSKit fails to run correctly on the Fujitsu variant of the SPARC64 architecture known as SPARC64-X. In most cases this manifests as a hang. Resolution: This issue has been resolved in GSKit build 8.0.50.60 for both 64-bit and 32-bit Solaris, but only in the non-FIPS mode of operation. Until our next FIPS certification, products experiencing this issue with the SSL API will need to ensure that they set GSK_ICC_NOLOAD_C to GSK_TRUE, and have not enabled the setting GSK_ICC_FIPS_MODE_PROCESSING to GSK_ICC_FIPS_MODE_PROCESSING_ON. For products using gsk8capicmd, some additional workarounds must be applied: In the envionment, set and export ICC_IGNORE_FIPS=yes Rename <gskit_install_location>/lib64/c to <gskit_install_location>/lib64/c_sav to get this directory out of the way. GSKit will then operate on Fujitsu hardware.
Local fix
Problem summary
Uplift the IBM Global Security Kit (GSKIT) shipped with IBM Tivoli Monitoring to version 8.0.50.69.
Problem conclusion
The IBM Global Security Kit (GSKIT) shipped with IBM Tivoli Monitoring has been uplifted to version 8.0.50.69. The fix for this APAR is contained in the following maintenance packages: | fix pack | 6.3.0-TIV-ITM-FP0007
Temporary fix
Comments
APAR Information
APAR number
IV85142
Reported component name
OMEG DIST INSTA
Reported component ID
5608A41CI
Reported release
630
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2016-05-27
Closed date
2016-11-18
Last modified date
2017-01-06
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
OMEG DIST INSTA
Fixed component ID
5608A41CI
Applicable component levels
[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSTFXA","label":"Tivoli Monitoring"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"630","Line of Business":{"code":"LOB45","label":"Automation"}}]
Document Information
Modified date:
08 March 2023