APAR status
Closed as program error.
Error description
Error Message: N/A . Stack Trace: _doprnt(??, ??, ??) at 0x20053ff8 <OSB>/usr/lib/libc.a(shr.o)<CSB>snprintf(....) at 0x2004b608 <OSB>untrusted: /usr/lib/libc.a(shr.o)<CSB>setAndRemember(.........), line 1954 in "java_md_solinux.c"setEnvVars(........), line 2051 in "java_md_solinux.c"unnamed block in CreateExecutionEnvironment(...........), line 627 in "java_md_solinux.c"unnamed block in CreateExecutionEnvironment(...........), line 627 in "java_md_solinux.c"CreateExecutionEnvironment(.............), line 627 in "java_md_solinux.c"unnamed block in JLI_Launch(..............), line 468 in "java.c"JLI_Launch(..............'), line 468 in "java.c"main(argc = 0, argv = (nil)), line 204 in "main.c" .
Local fix
Not available
Problem summary
When the pid of a Java process exceeds 6 character length on AIX , JVM will crash
Problem conclusion
JVM has been updated to accommodate upto 8 characters for pid (the max possible) . This APAR will be fixed in the following Java Releases: 7 SR9 (7.0.9.0) 7 R1 SR3 (7.1.3.0) 8 SR1 (8.0.1.0) . Contact your IBM Product's Service Team for these Service Refreshes and Fix Packs. For those running stand-alone, information about the available Service Refreshes and Fix Packs can be found at: https://www.ibm.com/developerworks/java/jdk/
Temporary fix
Comments
APAR Information
APAR number
IV69759
Reported component name
JAVA CLASS LIBS
Reported component ID
620700130
Reported release
700
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2015-02-21
Closed date
2015-04-01
Last modified date
2015-04-01
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
JAVA CLASS LIBS
Fixed component ID
620700130
Applicable component levels
R700 PSY
UP
R800 PSY
UP
[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSNVBF","label":"Runtimes for Java Technology"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"7.0","Line of Business":{"code":"LOB36","label":"IBM Automation"}}]