IBM Support

IV69759: CRASH IN JVM WHEN PID GREATER THAN 6 DIGITS NUMBER ON AIX

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • Error Message: N/A
    .
    Stack Trace: _doprnt(??, ??, ??) at 0x20053ff8
    <OSB>/usr/lib/libc.a(shr.o)<CSB>snprintf(....) at 0x2004b608
    <OSB>untrusted:
    /usr/lib/libc.a(shr.o)<CSB>setAndRemember(.........), line 1954
    in "java_md_solinux.c"setEnvVars(........), line 2051 in
    "java_md_solinux.c"unnamed block in
    CreateExecutionEnvironment(...........), line 627 in
    "java_md_solinux.c"unnamed block in
    CreateExecutionEnvironment(...........), line 627 in
    "java_md_solinux.c"CreateExecutionEnvironment(.............),
    line 627 in "java_md_solinux.c"unnamed block in
    JLI_Launch(..............), line 468 in
    "java.c"JLI_Launch(..............'), line 468 in
    "java.c"main(argc = 0, argv = (nil)), line 204 in "main.c"
    .
    

Local fix

  • Not available
    

Problem summary

  • When the pid of a Java process exceeds 6 character length on AIX
    , JVM will crash
    

Problem conclusion

  • JVM  has been updated to accommodate upto 8 characters for pid
    (the max possible)
    .
    This APAR will be fixed in the following Java Releases:
       7    SR9       (7.0.9.0)
       7 R1 SR3       (7.1.3.0)
       8    SR1       (8.0.1.0)
    .
    Contact your IBM Product's Service Team for these Service
    Refreshes and Fix Packs.
    For those running stand-alone, information about the available
    Service Refreshes and Fix Packs can be found at:
               https://www.ibm.com/developerworks/java/jdk/
    

Temporary fix

Comments

APAR Information

  • APAR number

    IV69759

  • Reported component name

    JAVA CLASS LIBS

  • Reported component ID

    620700130

  • Reported release

    700

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2015-02-21

  • Closed date

    2015-04-01

  • Last modified date

    2015-04-01

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    JAVA CLASS LIBS

  • Fixed component ID

    620700130

Applicable component levels

  • R700 PSY

       UP

  • R800 PSY

       UP