Error Message: When setting multiple trace options at run time either via JVMTI or com.ibm.jvm.Trace.set() the messages JVMTRCE000E and JVMTRCE002E are issued. The options that were passed in are not shown in the error message.Example:JVMTRCE000E Trace option unrecognized: -Xtrace:JVMTRCE002E Error processing trace option: -Xtrace:= . Stack Trace: N/A .
Local fix
The problem is seen when more than two trace options are specified at once, for example:Trace.set("none=all,maximal=j9mm,maximal=j9trc,maximal=j 9dmp,maximal=mt");If the options are passed individually the problem will not occur and the trace engine will be configured identically.Trace.set("none=all");Trace.set("maximal=j9mm");Trac e.set("maximal=j9trc");Trace.set("maximal=j9dmp");Trace.set("max imal=mt");
Problem summary
The problem was caused by incorrect handling of the options string.
Problem conclusion
The JVM has been updated to handle the options correctly. . This APAR will be fixed in the following Java Releases: 7 R1 SR2 FP10 (7.1.2.10) 6 SR16 FP3 (6.0.16.3) 6 R1 SR8 FP3 (6.1.8.3) 7 SR8 FP10 (7.0.8.10) . Contact your IBM Product's Service Team for these Service Refreshes and Fix Packs. For those running stand-alone, information about the Service Refreshes and Fix Packs can be found at: https://www.ibm.com/developerworks/java/jdk/
Temporary fix
Comments
APAR Information
APAR number
IV67532
Reported component name
J9 COMMON CODE
Reported component ID
620700127
Reported release
270
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2014-12-04
Closed date
2014-12-04
Last modified date
2014-12-04
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
J9 COMMON CODE
Fixed component ID
620700127
Applicable component levels
R270 PSY
UP
R600 PSY
UP
R260 PSY
UP
[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSNVBF","label":"Runtimes for Java Technology"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"7.0","Line of Business":{"code":"LOB36","label":"IBM Automation"}}]
Document Information
Modified date:
21 February 2022