Error description

  • The method findStorageSubSystemsInBusApp is taking a long time,
    in this case, 20 minutes. One of it's algorithms generates
    redundant getAllObjectAttributes on each Computer System
    connected to the StorageSubSystem.
    
    The algorithm has been optimized to remove those redundant
    calls.
    
    In the log when this happend you will see the call to this
    method and then a long time later the return(or not return at
    all). For example, note the time difference here;
    
    2014-08-25 15:21:20,208 ViewManager [RMI TCP
    Connection(488)-1.2.3.4]  DEBUG finder.CustomNodeFinderImpl -
    executeCustomNodeFinder(finderClassName=com.collation.proxy.view
    mgr.finder.FCSwitchStorageSubSystemFinder,
    finderMethodName=findStorageSubSystemsInBusApp,
    view=ViewDescriptor [type: Graph, view name: Application
    Physical Infrastructure Topology, version: 0, referring
    component id (option
    al):
    
    ..
    
    
    2014-08-25 15:42:10,816 ViewManager [RMI TCP
    Connection(488)-1.2.3.4]  DEBUG finder.CustomNodeFinderImpl -
    executeCustomNodeFinder() - Custom finder
    com.collation.proxy.viewmgr.finder.FCSwitchStorageSubSystemFinde
    r.findStorageSubSystemsInBusApp returned no results
    

Local fix

  • NA
    

Problem summary

  • The method findStorageSubSystemsInBusApp is taking a long time,
    in this case, 20 minutes. One of it's algorithms generates
    redundant getAllObjectAttributes on each Computer System
    connected to the StorageSubSystem.
    
    The algorithm has been optimized to remove those redundant
    calls.
    
    In the log when this happend you will see the call to this
    method and then a long time later the return(or not return at
    all). For example, note the time difference here;
    
    2014-08-25 15:21:20,208 ViewManager íRMI TCP
    Connection(488)-1.2.3.4ù  DEBUG finder.CustomNodeFinderImpl -
    executeCustomNodeFinder(finderClassName=com.collation.proxy.view
    mgr.finder.FCSwitchStorageSubSystemFinder,
    finderMethodName=findStorageSubSystemsInBusApp,
    view=ViewDescriptor ítype: Graph, view name: Application
    Physical Infrastructure Topology, version: 0, referring
    component id (option
    al):
    
    ..
    
    
    2014-08-25 15:42:10,816 ViewManager íRMI TCP
    Connection(488)-1.2.3.4ù  DEBUG finder.CustomNodeFinderImpl -
    executeCustomNodeFinder() - Custom finder
    com.collation.proxy.viewmgr.finder.FCSwitchStorageSubSystemFinde
    r.findStorageSubSystemsInBusApp returned no results
    

Problem conclusion

  • The fix for this APAR is contained in the following maintenance
    packages:
    | Fix Pack | 7.2.2-TIV-ITADDM-FP0003
    Check the IBM Software Support web site for availability of the
    above maintenance packages.
    

Temporary fix

Comments

APAR Information

  • APAR number

    IV64671

  • Reported component name

    APP DEPENDENCY

  • Reported component ID

    5724N5500

  • Reported release

    722

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2014-09-08

  • Closed date

    2014-10-20

  • Last modified date

    2014-10-20

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    APP DEPENDENCY

  • Fixed component ID

    5724N5500

Applicable component levels

  • R722 PSY

       UP

[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSPLFC","label":"Tivoli Application Dependency Discovery Manager"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"722","Edition":"","Line of Business":{"code":"LOB45","label":"Automation"}}]