IBM Support

IV57317: ILLEGAL INSTRUCTION EXCEPTION IN COMPILED JAVA METHOD

Subscribe to this APAR

By subscribing, you receive periodic emails alerting you to the status of the APAR, along with a link to the fix after it becomes available. You can track this item individually or track all items by product.

Notify me when this APAR changes.

Notify me when an APAR for this component changes.

 

APAR status

  • Closed as program error.

Error description

  • Error Message: An illegal instruction exception is raised in an
    AOT-compiled method.
    .
    Stack Trace: N/A
    .
    This issue affects both z/OS and z/Linux when a Java program is
    run with an agent that performs bytecode instrumentation and
    class sharing is enabled (with the -Xshareclasses option).
    

Local fix

  • This problem can be avoided by disabling class sharing, by
    removing the JVMTI agent, or by setting the JVM option
    -Xaot:exclude={full method name},loadExclude={full method name}
    for the method that is causing the issue. Disabling class
    sharing may cause some performance degradation.
    

Problem summary

  • The problem is caused by missing revocations in the AOT-compiled
    method for cases when method execution needs to revert back to
    interpretation.
    

Problem conclusion

  • This APAR will be fixed in the following Java Releases:
       7 R1 SR1       (7.1.1.0)
       7    SR7       (7.0.7.0)
       6 R1 SR8       (6.1.8.0)
       6    SR16      (6.0.16.0)
    .
    The JIT compiler has been updated to handle such cases properly.
    

Temporary fix

Comments

APAR Information

  • APAR number

    IV57317

  • Reported component name

    JIT

  • Reported component ID

    620700124

  • Reported release

    130

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2014-03-22

  • Closed date

    2014-04-02

  • Last modified date

    2014-04-02

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    JIT

  • Fixed component ID

    620700124

Applicable component levels

  • R130 PSY

       UP

  • R260 PSY

       UP

  • R600 PSY

       UP

[{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSC9HBA","label":"Just In Time (JIT) Compiler"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"130","Edition":"","Line of Business":{"code":"","label":""}}]

Document Information

Modified date:
02 April 2014