Error description
A value of -1 is incorrectly displayed as 4294967295. RECREATE INSTRUCTIONS: A simmple way to reproduce this is to connect a 64-bit klz agent to a 64-bit TEMS running on RedHat Linux. Author a situation using the KLZ_CPU attribute group and just specify the CPU_ID attribute and setting the condition to be equal to Aggregate. In addition, set the KLZ_CPU attribute as a display item. Messages like the following will be issued to the TEMS operations/MSG2 log: Thu Feb 6 17:23:32 2014 KO41041 Enterprise situation A_Sit:TVT4158:LZ<4294967295> is true. ~~~~~~~~~~ Approver Initials: HT
Local fix
No workaround available.
Problem summary
Display Item with value of -1 displays in Tivoli Enterprise Portal client as 4294967295. In the case of a situation definition that includes a Display Item, where said Display Item is a 4 byte integer type containing a negative value, the Display Item value will be incorrect in the Situation Event Console and the portal client Message Log; it will also be incorrect in the message recorded in the Tivoli Enterprise Monitoring server Operation (MSG2) log. This incorrect Display Item value only manifests on some operating system platforms, notably on Linux 64 bit platform. Note, this defect only affects Display Item form of a monitored attribute; it does not affect the attribute's value in context of situation's formula (predicate) evaluation
Problem conclusion
Changes were made to the logic to correctly convert negative valued Display Item. The fix for this APAR is included in the following maintenance vehicle: | fix pack | 6.3.0-TIV-ITM-FP0006 Note: Search the IBM technical support web site for maintenance package availability.
Temporary fix
Comments
APAR Information
APAR number
IV55651
Reported component name
TEMS
Reported component ID
5724C04MS
Reported release
630
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2014-02-19
Closed date
2015-07-27
Last modified date
2015-12-10
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
TEMS
Fixed component ID
5724C04MS
Applicable component levels
R630 PSY
UP
[{"Line of Business":{"code":"LOB45","label":"Automation"},"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSTFXA","label":"Tivoli Monitoring"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"630"}]
Document Information
Modified date:
30 December 2022