A fix is available
APAR status
Closed as program error.
Error description
A situation based on the attribute CPU Idle Pct in the Processor attribute group triggeres if run before the second data collection. Reported Release: 622 FP5 Approver: MK
Local fix
Problem summary
A situation based on the "% Idle Used" attribute in the "KR6 SMA Processor" attribute group triggers erroneously at startup.
Problem conclusion
The "% Idle Used" attribute value is based on the calculation of several attributes which are defined as SNMP Counter values. These values can grow over time, so the code calculates the delta from the current collected value with the previously collected value. If the situation runs at startup before the second data collection, the attribute would be set to 0 and the situation would trigger. Code has been updated to handle this condition correctly. This only affects the Agentless Monitor Solaris when configured with the Connection Type of "SNMP (System Management Agent)". The fix for this APAR is contained in the following maintenance packages: | fix pack | 6.3.0-TIV-ITM-FP0004
Temporary fix
Comments
APAR Information
APAR number
IV53401
Reported component name
ITM REMOTE SOLA
Reported component ID
5724C04RS
Reported release
622
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2013-12-16
Closed date
2014-06-23
Last modified date
2014-12-12
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
ITM REMOTE SOLA
Fixed component ID
5724C04RS
Applicable component levels
R630 PSY
UP
[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSTFXA","label":"Tivoli Monitoring"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"622","Line of Business":{"code":"LOB45","label":"Automation"}}]
Document Information
Modified date:
30 December 2022