APAR status
Closed as program error.
Error description
Error Message: UnsupportedOperationException . Stack Trace: java.lang.UnsupportedOperationException: This method is in the sun.* namespace so it is not a supported, public interface. at sun.reflect.Reflection.getCallerClass .
Local fix
Calls to sun.reflect.Reflection.getCallerClass(int depth) can be enabled by using the command line option -Djdk.reflect.allowGetCallerClass=true
Problem summary
An UnsupportedOperationException is now thrown when the sun.reflect.Reflection.getCallerClass(int depth) method is called, unless a command line option is used to revert to the original behavior.
Problem conclusion
This defect will be fixed in: 7.0.0 SR6 6.0.1 SR7 . The sun.reflect.Reflection.getCallerClass(int depth) method is disabled, and a command line option is provided to revert to the original behavior.
Temporary fix
Comments
APAR Information
APAR number
IV51263
Reported component name
J9 COMMON CODE
Reported component ID
620700127
Reported release
260
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2013-10-24
Closed date
2013-10-24
Last modified date
2013-10-25
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
J9 COMMON CODE
Fixed component ID
620700127
Applicable component levels
R260 PSY
UP
[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSNVBF","label":"Runtimes for Java Technology"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"6.1","Line of Business":{"code":"LOB36","label":"IBM Automation"}}]