IBM Support

IV32048: VIOSBR BACKUP FAILURE FOR ADAPTER WITH DUPLICATE LOC CODE

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • While running viosbr
    viosbr -backup -file myfilename
    Error adding sisscsia1 to table
    Error backing up VIOS config data for controller
    ERROR: ERROR while processing sisscsia1
    ERROR: Error backing up VIOS config data for CONTROLLERS
    ERROR-  Error backing up VIOS config data
    
    This only happens when there are duplicate location codes
    for sisscsi adapters
    ala
    sisscsia0 Available 03-08 U1234.001.DQDTWGM-P1
        PCI-X Ultra320 SCSI Adapter
    sisscsia1 Available 0A-08 U1234.001.DQDTWGM-P1
        PCI-X Ultra320 SCSI Adapter
    
    NOTE:  this is not for duplicate USB or LHEA adapters,
    those are addressed under IV18224
    

Local fix

  • Work around:  Remove duplicate adapter if it is
    unnecessary
    

Problem summary

  • VIOS backup and restore fails when PCI-X Ultra320
    dual channel SCSI adapter with same Location Code
    (DRC) are present.
    
    viosbr command may throw up errors similar to:
    Error adding sisscsia1 to table
    Error backing up VIOS config data for controller
    ERROR: ERROR while processing sisscsia1
    ERROR: Error backing up VIOS config data for CONTROLLERS
    ERROR-  Error backing up VIOS config data
    

Problem conclusion

  • The PCI-X Ultra320 dual channel SCSI adapters can have same DRC
    and viosbr code is fixed to handle this situation.
    

Temporary fix

Comments

APAR Information

  • APAR number

    IV32048

  • Reported component name

    VIRTUAL I/O SER

  • Reported component ID

    5765G3400

  • Reported release

    220

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2012-11-16

  • Closed date

    2013-02-22

  • Last modified date

    2013-08-02

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    IV38765 IV39003

Fix information

  • Fixed component name

    VIRTUAL I/O SER

  • Fixed component ID

    5765G3400

Applicable component levels

  • R220 PSY U859170

       UP13/08/02 I 1000

Fix is available