APAR status
Closed as program error.
Error description
Problem Description: ITCAM Extended Agent calculated wrong value for attribute of Buffer Cache Hit Ratio. This is due to the agent uses wrong parameter 'physical reads' from Oracle performance view v$systat. The correct parameter should be 'physical reads cache'. Detailed Recreation Procedure: Install and configure agent, then go to the navigator view from Node: Cache to Workspace: Buffer Cache, then check the value of '% Buffer Cache Hit'.
Local fix
N/A
Problem summary
************************************************************* * USERS AFFECTED: ITCAM Extended Agent for Oracle Database 6.3.1 Fix pack 1 ************************************************************* * PROBLEM DESCRIPTION: ITCAM Extended Agent calculated wrong value for attribute of Buffer Cache Hit Ratio. This is due to the agent uses wrong parameter 'physical reads' from Oracle performance view v$systat. The correct parameter should be 'physical reads cache'. ************************************************************* * RECOMMENDATION: apply next ifix or fixpack when available *************************************************************
Problem conclusion
The fix for this APAR is contained in the following packages: IBM Tivoli Composite Application Manager Extended Agent for Oracle Database 6.3.1-TIV-ITM_KRZ-IF0002
Temporary fix
Comments
APAR Information
APAR number
IV27682
Reported component name
ITCAM EXT AGNT
Reported component ID
5724V09OR
Reported release
631
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2012-09-11
Closed date
2013-05-12
Last modified date
2014-02-28
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
ITCAM EXT AGNT
Fixed component ID
5724V09OR
Applicable component levels
R631 PSY
UP
[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SS3JRN","label":"Tivoli Composite Application Manager for Applications"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"6.3.1","Edition":"","Line of Business":{"code":"LOB45","label":"Automation"}}]