IBM Support

IV10404: PSW2.2 - PSSERVICE IS CONSUMING HIGH CPU USAGE AFTER AGENT UPDATE TO 2.2.166.292

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • phService had high CPU usage detected by HP OpenView on 8
    servers
    - All in Wiesbaden
    - All WS08R2 VMs
    - 8 machines total, 2 DC, others are various uses
    - Restarted phService to resolve the problem and the problem has
    not
    happened again.
    - When stopping phService in all cases the service wouldn't stop
    correctly (Problem encountered stopping phService) and blackd
    had to be
    stopped independently.  The phService.exe process would exit
    during
    service shutdown however.
    - Many messages in the system log about phService not responding
    and
    timing out.  This happens every 15 minutes and no one is
    attempting to
    stop or start the service.
    Event ID: 7011 "A timeout (30000 milliseconds) was reached
    waiting for a
    transaction response from IBMProventia service."
    - All blackd switched from automatic to manual after problem
    occurred so
    that might be related since it stopped happening.
    - 3 Provinfo logs gathered while the machines were in a high CPU
    state.
    

Local fix

  • right now there is no workarround. L3 are working on this issue
    to provide a Fix
    

Problem summary

  • Made change to reduce cpu usage in certain cases.
    

Problem conclusion

  • This fix will be included in all future releases.
    

Temporary fix

Comments

APAR Information

  • APAR number

    IV10404

  • Reported component name

    PSW IPS

  • Reported component ID

    5608T18SW

  • Reported release

    21E

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2011-11-10

  • Closed date

    2012-06-26

  • Last modified date

    2012-06-26

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    PSW IPS

  • Fixed component ID

    5608T18SW

Applicable component levels

  • R220 PSY

       UP