Fixes are available
APAR status
Closed as program error.
Error description
TEMS crash with the following call stack if KPX trace is enabled kbb!RAS1_Format+0x36 kbb!RAS1_Printf+0x1f KRANDREG!CTIRA_FindAttrStart+0x1cf KRANDREG!IRA_NCS_Subnode_Request+0x310 KRANDREG!IRA_NCS_Subnode_Request_ssr+0x869 Approver Initials: LK
Local fix
Turn off KPX trace
Problem summary
The monitoring server crashes after turning on KPX trace Incorrectly calculated print format precision specifier causes the monitoring server to crash if KPX trace is enabled:
Problem conclusion
The monitoring server subnode registration module now correctly calculates print formatting precision. The fix for this APAR is contained in the following maintenance packages: | fix pack | 6.2.2-TIV-ITM-FP0007
Temporary fix
Comments
APAR Information
APAR number
IV06261
Reported component name
TEMA
Reported component ID
5724C04TE
Reported release
622
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2011-08-15
Closed date
2011-09-13
Last modified date
2011-12-15
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
TEMA
Fixed component ID
5724C04TE
Applicable component levels
R622 PSY
UP
[{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCTLMR","label":"ITM Tivoli Enterprise Mgmt Agent V6"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"622","Edition":"","Line of Business":{"code":"","label":""}}]
Document Information
Modified date:
15 December 2011