A fix is available
APAR status
Closed as program error.
Error description
When etherchannel is made of bentdd(devices.pci.e414a816, Gigabit Ethernet-SX Adapter) as a primary adapter on blade system, and when system reboots, the link of the primary adapter remains down. If the same adapter configured as backup in etherchannel, then link comes up.
Local fix
Problem summary
When etherchannel is made of bentdd(devices.pci.e414a816, Gigabit Ethernet-SX Adapter) as a primary adapter on blade system, and when system reboots, the link of the primary adapter remains down.
Problem conclusion
Link watchdog timer is turned on after adapter is started.
Temporary fix
Comments
5300-11 - use AIX APAR IV04462 5300-12 - use AIX APAR IZ99180 6100-04 - use AIX APAR IV05679 6100-05 - use AIX APAR IV05328 6100-06 - use AIX APAR IV04988 7100-00 - use AIX APAR IV26427
APAR Information
APAR number
IV04462
Reported component name
AIX 5.3
Reported component ID
5765G0300
Reported release
530
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Submitted date
2011-08-03
Closed date
2011-08-03
Last modified date
2013-04-16
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
AIX 5.3
Fixed component ID
5765G0300
Applicable component levels
R530 PSY U844858
UP11/10/07 I 1000
PTF to Fileset Mapping
U844858 devices.pci.e414a816.rte 5.3.11.1