A fix is available
APAR status
Closed as program error.
Error description
msnentdd - 10 Gb Ethernet PCI Express Dual Port Adapter (7710008077108001) does not configure correctly in etherchannel environment. The adapter link never comes up. When IPs are configured directly on the adapter it works (non-etherchannel mode).
Local fix
Problem summary
we can no longer send commands to the MPI firmware
Problem conclusion
We need to reset the mpi_cmd_list, and the flag has to be reseted to zero.
Temporary fix
Comments
APAR Information
APAR number
IV04310
Reported component name
AIX 5.3
Reported component ID
5765G0300
Reported release
530
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Submitted date
2011-08-03
Closed date
2011-08-03
Last modified date
2013-04-07
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
AIX 5.3
Fixed component ID
5765G0300
Applicable component levels
R530 PSY U844681
UP11/10/10 I 1000
PTF to Fileset Mapping
U844681 devices.pciex.771000801410b003.rte 5.3.12.3