APAR status
Closed as program error.
Error description
Using the RSA PSS verification might cause the DataPower appliance to reload abruptly. This problem only occurs on 53X platform.
Local fix
Problem summary
Prevent the restart when HSM is uninitialized.
Problem conclusion
The fix is in 10.5.0.10 & 10.0.1.18
Temporary fix
Comments
APAR Information
APAR number
IT45032
Reported component name
DATAPOWER
Reported component ID
DP1234567
Reported release
A0X
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2023-11-27
Closed date
2024-05-16
Last modified date
2024-05-16
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
DATAPOWER
Fixed component ID
DP1234567
Applicable component levels
[{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SS9H2Y","label":"IBM DataPower Gateways"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"A0X","Line of Business":{"code":"LOB67","label":"IT Automation \u0026 App Modernization"}}]
Document Information
Modified date:
16 May 2024