Error description

  • Although scheduled data collection was successful for some
    storage systems, any attempts to restart data collection were
    not initiated as expected.  The date and time shown for the last
    successful probe was not updated as no new probe was run.  The
    performance monitors were not restarted either.  Any attempts to
    Modify Schedule for the same devices resulted in an error.
    
    When looking at the data collector details pages, multiple data
    collectors reported "monitoring" for the same storage system.
    Each device should only be actively monitored by one data
    collector at a time, even if other data collectors are
    "allowed".
    

Local fix

  • Database was cleaned up to remove some incorrect/stale entries.
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED:                                              *
    * IBM Storage Insights users uploading support data for        *
    * storage device                                               *
    *                                                              *
    ****************************************************************
    * PROBLEM DESCRIPTION:                                         *
    * Although scheduled data collection was successful for        *
    * some storage systems, any attempts to restart data           *
    * collection                                                   *
    * were not initiated as expected.  The date and time shown for *
    *                                                              *
    * the last successful probe was not updated as no new probe    *
    * was run.  The performance monitors were not restarted        *
    * either.                                                      *
    * Any attempts to Modify Schedule for the same devices         *
    * resulted                                                     *
    * in an error.                                                 *
    *                                                              *
    * When looking at the data collector details pages, multiple   *
    * data                                                         *
    * collectors reported "monitoring" for the same storage        *
    * system.                                                      *
    * Each device should only be actively monitored by one data    *
    * collector at a time, even if other data collectors are       *
    * "allowed".                                                   *
    ****************************************************************
    * RECOMMENDATION:                                              *
    * If you encountered this problem prior to the                 *
    * 4Q 2023 / November release, contact IBM                      *
    * Support for resolution.                                      *
    ****************************************************************
    

Problem conclusion

  • The fix for this APAR is targeted for the following release:
    
    IBM Storage Insights 4Q23   [ 54X-IBM-SI ]
    ( release target 4Q 2023 / November )
    
    The target dates for future releases do not represent a formal
    commitment by IBM. The dates are subject to change without
    notice.
    

Temporary fix

Comments

APAR Information

  • APAR number

    IT44666

  • Reported component name

    STORAGE INSIGHT

  • Reported component ID

    5608TPCSI

  • Reported release

    54X

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2023-10-04

  • Closed date

    2023-11-06

  • Last modified date

    2023-11-06

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    STORAGE INSIGHT

  • Fixed component ID

    5608TPCSI

Applicable component levels

[{"Business Unit":{"code":"BU029","label":"Software"},"Product":{"code":"SSYS7R","label":"IBM Spectrum Control Storage Insights"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"54X"}]

Document Information

Modified date:
07 November 2023