Error description

  • An MQ input node is consuming messages from a remote queue
    manager using MQEndpoint policy configured on the node. The
    MQEndpoint policy is configured to allow reconnect.
    
    When 'Allow Reconnect' is enabled a new return code is possible
    MQRC_RECONNECT_FAILED, but this return code is not listed in the
    set of return codes which require the connection to be re-made
    so ACE does not disconnect and re-connect so no more messages
    are delivered to the input node.
    

Local fix

Problem summary

  • ****************************************************************
    USERS AFFECTED:
    <span style="background-color:rgb(255, 255, 255)">All users of
    the IBM App Connect Enterprise v11 and V12 using MQInput
    Node</span>
    
    
    Platforms affected:
    MultiPlatform
    
    ****************************************************************
    PROBLEM DESCRIPTION:
    MQ input node can be configured to consume messages from a
    remote queue manager using MQEndpoint policy configured on the
    node.
    
    When 'Allow Reconnect' option is enabled in  MQEndpoint  policy,
    a new return code MQRC_RECONNECT_FAILED is possible, however,
    this return code is not listed in the set of return codes which
    require the connection to be re-established. So when the
    connection errors out with MQRC_RECONNECT_FAILED,  the message
    flow does not attempt re-connection to the remote queue manager,
    and therefore no further messages are delivered to the input
    node.   Following error is typically observed in the logs:
    
    BIP2628W: Exception condition detected on input node
    'xxxxxxxxx'.
    BIP2680E: Failed to setup a MQ control callback for component
    'yyyyyyyyy' to queue 'AAAAAA' on queue manager 'ZZZZ': MQCC=2;
    MQRC=2548.
    

Problem conclusion

  • Product now handles MQRC_RECONNECT_FAILED return code and allows
    connection to be re-established with the queue manager.
    
    ---------------------------------------------------------------
    The fix is targeted for delivery in the following PTFs:
    
    Version    Maintenance Level
    v11.0      11.0.0.21
    v12.0      12.0.8.0
    
    The latest available maintenance can be obtained from:
    http://www-01.ibm.com/support/docview.wss?rs=849&uid=swg27006041
    
    If the maintenance level is not yet available,information on
    its planned availability can be found on:
    http://www-1.ibm.com/support/docview.wss?rs=849&uid=swg27006308
    ---------------------------------------------------------------
    

Temporary fix

Comments

APAR Information

  • APAR number

    IT42882

  • Reported component name

    APP CONNECT ENT

  • Reported component ID

    5724J0560

  • Reported release

    C00

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2023-01-11

  • Closed date

    2023-04-13

  • Last modified date

    2023-08-24

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    APP CONNECT ENT

  • Fixed component ID

    5724J0560

Applicable component levels

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSDR5J","label":"IBM App Connect Enterprise"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"C00","Line of Business":{"code":"LOB45","label":"Automation"}}]

Document Information

Modified date:
24 August 2023