APAR status
Closed as program error.
Error description
In 10.5.0.3 a new feature was added to the API Plan which would allow plan-scoped scale assembly limits; but a misconfiguration of the limits could result in the gateway restarting. e.g. rate-limit-definition x01 type count ... exit api-plan x01 assembly-burst-limit-def definition x01
Local fix
Verify that the Rate Limit Definition matches the Plan rate limit type.
Problem summary
Datapower may restart if the user sets the wrong type of RateLimitDefinition in the plan-scoped scale assembly limits to the API Plan.
Problem conclusion
Fix is available in 10.5.0.4 For a list of the latest fix packs available, please see: http://www-01.ibm.com/support/docview.wss?uid=swg21237631
Temporary fix
To correct the wrong RateLimitDefinition type.
Comments
APAR Information
APAR number
IT42772
Reported component name
DATAPOWER
Reported component ID
DP1234567
Reported release
A5X
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2023-01-26
Closed date
2023-02-17
Last modified date
2023-02-21
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
DATAPOWER
Fixed component ID
DP1234567
Applicable component levels
[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SS9H2Y","label":"IBM DataPower Gateways"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"A5X","Line of Business":{"code":"LOB45","label":"Automation"}}]
Document Information
Modified date: