IT41960: THE DATADIRECT ORACLE ODBC DRIVER INCORRECTLY RESOLVES TIMESTAMP(S)

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as change to accomodate OEM Vendor's code.

Error description

  • When two (or more) calls are made to the oracle 'TO_TIMEZONE_TZ'
    function in a single SQL statement
    
    then the first parameter of the first call to the function is
    incorrectly described and bound.
    
    If only a single call is made to the oracle 'TO_TIMEZONE_TZ'
    function the error does not occur.
    
    For example
    INSERT INTO MY_TABLE (DATE1, DATE2) VALUES
    (TO_TIMESTAMP_TZ(?,?), TO_TIMESTAMP_TZ(?,?))
    will result an error like this when it is executed
    [IBM][ODBC Oracle Wire Protocol driver][Oracle]ORA-01852:
    seconds must be between 0 and 59
    

Local fix

Problem summary

  • ****************************************************************
    USERS AFFECTED:
    All users of App Connect Enterprise Version 11 or Version 12 who
    use the Oracle database TO_TIMEZONE_TZ function.
    
    
    Platforms affected:
    AIX, Linux on Power platform, Linux on x86-64 platform, Linux on
    zSeries platform, Windows on x86-64 platform
    
    ****************************************************************
    PROBLEM DESCRIPTION:
    When two (or more) calls are made to the oracle 'TO_TIMEZONE_TZ'
    function in a single SQL statement the first parameter of the
    first call
    to the function is incorrectly described and bound.
    
    INSERT INTO MY_TABLE (DATE1, DATE2) VALUES
    (TO_TIMESTAMP_TZ(?,?), TO_TIMESTAMP_TZ(?,?))
    will result an error like this when it is executed
    [IBM][ODBC Oracle Wire Protocol driver][Oracle]ORA-01852:
    seconds must be between 0 and 59
    

Problem conclusion

  • A new DataDirect Oracle ODBC driver that fixes the error is now
    supplied with App Connect Enterprise.
    

Temporary fix

Comments

APAR Information

  • APAR number

    IT41960

  • Reported component name

    APP CONNECT ENT

  • Reported component ID

    5724J0560

  • Reported release

    C00

  • Status

    CLOSED OEM

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2022-09-06

  • Closed date

    2022-09-20

  • Last modified date

    2022-09-20

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

Applicable component levels

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSDR5J","label":"IBM App Connect Enterprise"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"C00","Line of Business":{"code":"LOB45","label":"Automation"}}]

Document Information

Modified date:
21 September 2022