IBM Support

IT41949: THE DESCRIPTION OF A DATABASE PARAMETER IS INCORRECT FOR A PARAMETER MARKER THAT FOLLOWS AN INCREMENTED COLUMN

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as change to accomodate OEM Vendor's code.

Error description

  • The actual values in the error message will depend on the type
    of the database column being describe after the incremented
    column.
    For example
    DatabaseException BIP2322E: Database error: SQL State ''07006'';
    Native Error Code '0'; Error Text ''[IBM][ODBC Oracle Wire
    Protocol driver]Unable to convert parameter 1. Cannot convert
    from C type 93 to SQL type 3.''.
    

Local fix

Problem summary

  • ****************************************************************
    USERS AFFECTED:
    All users of IBM Integration Bus Version 10 or App Connect
    Enterprise Version 11 or Version 12 who use an Oracle database
    where an incremented column is used in a database statement.
    
    
    Platforms affected:
    AIX, HP-UX PA-RISC platform, HP-UX Itanium platform, Linux on
    Power platform, Linux on x86-64 platform, Linux on zSeries
    platform, Solaris x86-64 platform, Solaris SPARC platform,
    Windows on x86-64 platform
    
    ****************************************************************
    PROBLEM DESCRIPTION:
    The DataDirect Oracle ODBC driver incorrectly described the
    columns that followed an incremented column in a database
    statement.
    
    For example in this update statement the database column
    'MyColumn3' would be incorrectly described.
    UPDATE Database.MyTable AS Z
          SET MyColumn1 = CURRENT_TIMESTAMP,
                 MyColumn2 = Z.MyColumn2 + 1,
                 MyColumn3 = MyNameVariable;
    

Problem conclusion

  • A new DataDirect Oracle ODBC driver that fixes the error is now
    supplied with App Connect Enterprise.
    

Temporary fix

Comments

APAR Information

  • APAR number

    IT41949

  • Reported component name

    INTEGRATION BUS

  • Reported component ID

    5724J0540

  • Reported release

    A00

  • Status

    CLOSED OEM

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2022-09-05

  • Closed date

    2022-09-08

  • Last modified date

    2022-09-08

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

Applicable component levels

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSNQK6","label":"IBM Integration Bus"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"10.0","Line of Business":{"code":"LOB45","label":"Automation"}}]