IT41086: AN ORA-01841 ERROR IS REPORTED WHEN UPDATING A TIMESTAMP COLUMN.

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as change to accomodate OEM Vendor's code.

Error description

  • The error occurs with the first TIMESTAMP column in a query
    following some form
    of string processing, such as REVERSE or SUBSTR.
    If no string processing is performed in the query then there is
    no error reported from the TIMESTAMP column.
    There is no error reported from TIMETAMP columns that precede
    the string processing in the query.
    

Local fix

  • It may be possible to work around this issue by reordering the
    database query so that no TIMESTAMP columns follow the
    string processing.
    

Problem summary

  • ****************************************************************
    USERS AFFECTED:
    All Users of IBM Integration Bus V10 and AppConnect Enterprise
    Versions 11 and 12 access an Oracle database using ODBC.
    
    
    Platforms affected:
    AIX, HP-UX Itanium platform, Linux on Power platform, Linux on
    x86-64 platform, Linux on zSeries platform, Solaris x86-64
    platform, Solaris SPARC platform, Windows on x86-64 platform
    
    ****************************************************************
    PROBLEM DESCRIPTION:
    An ORA-01841 error message is returned when a database query
    that performs some form of string processing then
    attempts to also use a TIMESTAMP column. The error occurs with
    the first TIMESTAMP column in a query that follows
    the string processing.
    The full oracle error message is "ORA-01841: (full) year must be
    between -4713 and +9999, and not be 0"
    

Problem conclusion

  • An update DataDirect Oracle ODBC driver has been supplied to
    correct the error.
    

Temporary fix

Comments

APAR Information

  • APAR number

    IT41086

  • Reported component name

    INTEGRATION BUS

  • Reported component ID

    5724J0540

  • Reported release

    A00

  • Status

    CLOSED OEM

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2022-05-31

  • Closed date

    2022-06-14

  • Last modified date

    2022-06-14

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

Applicable component levels

[{"Line of Business":{"code":"LOB45","label":"Automation"},"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSNQK6","label":"IBM Integration Bus"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"10.0"}]

Document Information

Modified date:
15 June 2022