IT39213: INPUT BITSTREAM IS NOT REUSED BY THE JSON PARSER IN SOME SITUATIONS WHERE IT COULD BE.

Subscribe to this APAR

By subscribing, you receive periodic emails alerting you to the status of the APAR, along with a link to the fix after it becomes available. You can track this item individually or track all items by product.

Notify me when this APAR changes.

Notify me when an APAR for this component changes.

 

APAR status

  • Closed as program error.

Error description

  • In order to maximise performance the parsers in IBM Integration
    Bus and App Connect Enterprise will often re-use the input
    bitstream when serialising if it has been detected as valid. In
    the case of the JSON parser when the serialisation encoding is 0
    and the input encoding matches the default encoding the input
    bitstream could be re-used but is not.
    
    
    This may be detectable due to differences in preservation of
    whitespace or escaped characters in the serialised output.
    

Local fix

Problem summary

  • ****************************************************************
    USERS AFFECTED:
    All users of IBM Integration Bus version 10 or App Connect
    Enterprise version 11 or 12 using the JSON parser.
    
    
    Platforms affected:
    MultiPlatform
    
    ****************************************************************
    PROBLEM DESCRIPTION:
    In order to maximise performance the parsers in IBM Integration
    Bus and App Connect Enterprise will often re-use the input
    bitstream when serialising if it has been detected as valid. In
    the case of the JSON parser when the serialisation encoding is 0
    and the input encoding matches the default encoding the input
    bitstream could be re-used but is not.
    
    
    This may be detectable due to differences in preservation of
    whitespace or escaped characters in the serialised output.
    

Problem conclusion

  • JSON parser instances are now eligible for re-use when the
    serialisation encoding is 0 and the input encoding matches the
    default encoding.
    
    ---------------------------------------------------------------
    The fix is targeted for delivery in the following PTFs:
    
    Version    Maintenance Level
    v11.0      11.0.0.17
    v12.0      12.0.4.0
    
    The latest available maintenance can be obtained from:
    http://www-01.ibm.com/support/docview.wss?rs=849&uid=swg27006041
    
    If the maintenance level is not yet available,information on
    its planned availability can be found on:
    http://www-1.ibm.com/support/docview.wss?rs=849&uid=swg27006308
    ---------------------------------------------------------------
    

Temporary fix

Comments

APAR Information

  • APAR number

    IT39213

  • Reported component name

    INTEGRATION BUS

  • Reported component ID

    5724J0540

  • Reported release

    A00

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2021-11-25

  • Closed date

    2023-04-05

  • Last modified date

    2023-04-05

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    INTEGRATION BUS

  • Fixed component ID

    5724J0540

Applicable component levels

[{"Business Unit":{"code":"BU029","label":"Software"},"Product":{"code":"SSNQK6","label":"IBM Integration Bus"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"10.0"}]