Error description

  • In ACE, its seen that the message tree propagated out of
    SOAPAsyncResponse node doesnt set Properties.MessageSet. This
    can cause failure when the node is connected to a collector node
     or to any other node that validates the message tree. Following
     error is reported when the SOAPAsyncResponse node is connected
    to a collector node
    
    
     BIP5026E: XML schema validation error: Unexpected root tag
    

Local fix

  • set the messageSet value using a compute node before the
    collector node
    

Problem summary

  • ****************************************************************
    USERS AFFECTED:
    All Users of App Connect Enterprise V11.0 and V12.0 with
    SOAPAsyncRequest-Response nodes.
    
    
    Platforms affected:
    MultiPlatform
    
    ****************************************************************
    PROBLEM DESCRIPTION:
    In ACE, it is seen that the message tree propagated out of
    SOAPAsyncResponse node does not set the Properties.MessageSet
    value. This can cause failure when the node is connected to a
    collector node or to any other node that validates the message
    tree. The following error is reported when the SOAPAsyncResponse
    node is connected to a collector node
    
    BIP5026E: XML schema validation error: Unexpected root tag
    

Problem conclusion

  • The <span style="background-color:rgb(255, 255,
    255)">SOAPAsyncResponse </span>node now sets the messageset
    value correctly in the message tree  while propagating the
    message out of the node.
    
    ---------------------------------------------------------------
    The fix is targeted for delivery in the following PTFs:
    
    Version    Maintenance Level
    v11.0      11.0.0.17
    v12.0      12.0.4.0
    
    The latest available maintenance can be obtained from:
    http://www-01.ibm.com/support/docview.wss?rs=849&uid=swg27006041
    
    If the maintenance level is not yet available,information on
    its planned availability can be found on:
    http://www-1.ibm.com/support/docview.wss?rs=849&uid=swg27006308
    ---------------------------------------------------------------
    

Temporary fix

Comments

APAR Information

  • APAR number

    IT39120

  • Reported component name

    APP CONNECT ENT

  • Reported component ID

    5724J0550

  • Reported release

    B00

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2021-12-02

  • Closed date

    2022-04-13

  • Last modified date

    2022-04-13

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    APP CONNECT ENT

  • Fixed component ID

    5724J0550

Applicable component levels

[{"Line of Business":{"code":"LOB45","label":"Automation"},"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSDR5J","label":"IBM App Connect Enterprise"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"B00"}]

Document Information