Error description
During an IBM Spectrum Protect Plus file system backup, an object (file) may change during the backup. When this happens the CTGGT0176 "Unable to read attributes/meta data" error is written to the job log for all objects that experience this behavior. Example: ERROR,CTGGT0176, Unable to read attributes/meta data for E:\ibm\myfile.txt. This error can be confusing or misleading to users and should be changed to something more descriptive. Keywords: TS005325533
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: * * IBM Spectrum Protect Plus level 10.1.7, 10.1.8, and 10.1.9 * **************************************************************** * PROBLEM DESCRIPTION: * * See ERROR DESCRIPTION * **************************************************************** * RECOMMENDATION: * * Apply fixing level when available. This problem is currently * * projected to be fixed IBM Spectrum Protect Plus level * * 10.1.10. Note that this is subject to change at the * * discretion of IBM. * ****************************************************************
Problem conclusion
The misleading message CTGGT0176 error is removed. Now in case that a file is deleted during the backup operation the warning message CTGGT0204 is reported and the backup operation continues. No action is required.
Temporary fix
Comments
APAR Information
APAR number
IT38683
Reported component name
SP PLUS
Reported component ID
5737SPLUS
Reported release
A17
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2021-10-12
Closed date
2022-02-09
Last modified date
2022-02-09
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Modules/Macros
Apps FileSys
Fix information
Fixed component name
SP PLUS
Fixed component ID
5737SPLUS
Applicable component levels
[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSNQFQ","label":"IBM Spectrum Protect Plus"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"A17","Line of Business":{"code":"LOB26","label":"Storage"}}]
Document Information
Modified date:
31 January 2024