Error description

  • If you have an application of the following form, running on IBM
    Integration Bus, it may fail after migrating to ACE V11.
    
    ++++++++
    Shared library containing 2 subflows. One inner subflow that has
    a UDP property and the inner subflow is added to an outer
    subflow .  The outer subflow has promoted the UDP (of the
    subflow node) to flow level. The outer subflow is then added to
    the main application and the value of UDP is set in the main
    application flow.
    ++++++
    

Local fix

  • Redeploy the subflows.
    

Problem summary

  • ****************************************************************
    USERS AFFECTED:
    All users of IBM App Connect Enterprise V12 and V11,  migrated
    from IBM Integration Bus,  having user-defined property on
    subflow node.
    
    
    Platforms affected:
    MultiPlatform
    
    ****************************************************************
    PROBLEM DESCRIPTION:
    <span style="background-color:rgb(255, 255, 255)">If you have an
    application of the following form, running on IBM </span><span
    style="background-color:rgb(255, 255, 255)">Integration Bus, it
    may fail after migrating to App Connect Enterprise.
    </span>
    <span style="background-color:rgb(255, 255, 255)">
    
    </span>
    <span style="background-color:rgb(255, 255, 255)">_____________
                                                        </span>
    <span style="background-color:rgb(255, 255, 255)">Shared library
    containing 2 subflows. One inner subflow that has  </span><span
    style="background-color:rgb(255, 255, 255)">a UDP property and
    the inner subflow is added to an outer </span><span
    style="background-color:rgb(255, 255, 255)">subflow .  The outer
    subflow has promoted the UDP (of the </span><span
    style="background-color:rgb(255, 255, 255)">subflow node) to
    flow level. The outer subflow is then added to </span><span
    style="background-color:rgb(255, 255, 255)">the main application
    and the value of UDP is set in the main </span><span
    style="background-color:rgb(255, 255, 255)">application flow.
                                                 </span>
    <span style="background-color:rgb(255, 255, 255)">____________
    
    An application of the above form,  when migrated to App Connect
    Enterprise V11 or V12,  will fail to override the UDP with the
    value set in main application flow. </span>
    

Problem conclusion

Temporary fix

Comments

APAR Information

  • APAR number

    IT38505

  • Reported component name

    APP CONNECT ENT

  • Reported component ID

    5724J0550

  • Reported release

    B00

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2021-09-27

  • Closed date

    2021-10-29

  • Last modified date

    2021-10-29

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    APP CONNECT ENT

  • Fixed component ID

    5724J0550

Applicable component levels

[{"Line of Business":{"code":"LOB45","label":"Automation"},"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSDR5J","label":"IBM App Connect Enterprise"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"B00"}]

Document Information

Modified date:
30 October 2021