IBM Support

IT37542: INTEGRATION SERVER NOT BEING STARTED IF .PID FILE EXISTS CONTAINING PROCESS ID OF ZERO

Subscribe to this APAR

By subscribing, you receive periodic emails alerting you to the status of the APAR, along with a link to the fix after it becomes available. You can track this item individually or track all items by product.

Notify me when this APAR changes.

Notify me when an APAR for this component changes.

 

APAR status

  • Closed as program error.

Error description

  • On startup, an integration server writes its process id to a
    file called .pid in the work path. On shutdown, the .pid file is
    normally removed. When an integration node restarts, it checks
    for the existence of these .pid files in case the integration
    node process had terminated abnormally and needs to adopt the
    still running integration servers on restart. If a .pid file
    exists for an integration server and contains the value 0, the
    integration node is incorrectly determining that the integration
    server is already running and does not attempt to start it.
    

Local fix

Problem summary

  • ****************************************************************
    USERS AFFECTED:
    All users of IBM App Connect Enterprise V11 and V12 on AIX.
    
    
    Platforms affected:
    MultiPlatform
    
    ****************************************************************
    PROBLEM DESCRIPTION:
    On startup, an integration server writes its process id to a
    file called .pid in the work path. On shutdown, the .pid file is
    normally removed. When an integration node restarts, it checks
    for the existence of these .pid files in case the integration
    node process had terminated abnormally and needs to adopt the
    still running integration servers on restart. On AIX, if a .pid
    file exists for an integration server and contains the value 0,
    the integration node is incorrectly determining that the
    integration server is already running and does not attempt to
    start it.
    

Problem conclusion

  • The product now does not attempt to adopt an integration server
    process if the .pid file contains the value zero.
    
    ---------------------------------------------------------------
    The fix is targeted for delivery in the following PTFs:
    
    Version    Maintenance Level
    v11.0      11.0.0.15
    v12.0      12.0.3.0
    
    The latest available maintenance can be obtained from:
    http://www-01.ibm.com/support/docview.wss?rs=849&uid=swg27006041
    
    If the maintenance level is not yet available,information on
    its planned availability can be found on:
    http://www-1.ibm.com/support/docview.wss?rs=849&uid=swg27006308
    ---------------------------------------------------------------
    

Temporary fix

Comments

APAR Information

  • APAR number

    IT37542

  • Reported component name

    APP CONNECT ENT

  • Reported component ID

    5724J0550

  • Reported release

    B00

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2021-07-08

  • Closed date

    2021-10-22

  • Last modified date

    2021-10-22

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    APP CONNECT ENT

  • Fixed component ID

    5724J0550

Applicable component levels

[{"Line of Business":{"code":"LOB45","label":"Automation"},"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSDR5J","label":"IBM App Connect Enterprise"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"B00"}]

Document Information

Modified date:
23 October 2021